Megger DCM1500S Solar Clamp Meter, 2000 V DC, 1500 V AC

Model: DCM1500S | Order No: 1013-357

Megger DCM1500S Solar Clamp Meter, 2000 V DC, 1500 V AC

Model: DCM1500S | Order No: 1013-357

Ideal for the installation and maintenance of solar and photovoltaic installations, this solar clamp meter measures current, volts, resistance, frequency, diode, capacitance, and temperature. In addition, this meter features a large backlit display and an automatic torch in the jaw to make it easier to use in dark areas.

Ideal for the installation and maintenance of solar and photovoltaic installations, this solar clamp meter measures current, volts, resistance, frequency, diode, capacitance, and temperature. In addition, this meter features a large backlit display and an automatic torch in the jaw to make it easier to use in dark areas.

Regular Price $885.00 CAD
Availability 2 to 3 Weeks
Quantity

Megger DCM1500S Offers

Remotely monitor measurement values on a smart device with this solar clamp meter which features built-in Bluetooth to view a live trend graph and sample and log the values for later analysis. Additionally, this meter features a high-frequency rejection filter, inrush current measurement, internal data logging, a non-contact volt seek mode, and manual DC Amp zeroing.

Features

  • 2000 V DC
  • TRMS 1500 V AC
  • 1500 A AC/DC
  • Smart hold
  • Auto ranging
  • Minimum/Maximum hold
  • Inrush current
  • Megger Link app compatible
  • CAT IV 600 V / CAT III 1000 V
  • Data logger
  • PV test leads with MC4PV plugs
  • 60000 counts digital display
  • Large white LED backlit display
  • True RMS reading on ACA/ACV
  • AC/DC μA Range
  • Resistance, diode, capacitance and frequency measurement
  • °C/°F temperature function
  • DCA zero
  • Torch light on trigger push
  • Data Logging up to 1000 records
  • Manual save mode
  • Auto power off
  • DC mV Range

Applications

  • Solar/photovoltaic installations
  • Electrical systems and equipment
  • Battery monitoring
  • Automotive
  • Charging and load circuits
  • Electric vehicle servicing
  • Lift maintenance
  • UPS commissioning, servicing and maintenance
  • Electro-plating plants and welding equipment servicing
  • Domestic power generation from solar panels and wind-turbines

The unit is designed to be used on electrical systems and equipment, including solar/photovoltaic installations where, there is a need to measure current, volts, resistance and frequency. It is therefore intended for use while installing, maintaining, fault-finding or monitoring those systems. The tactile barrier below the jaws of the instrument ensures a safe working distance for the operator's hand when measuring current on live uninsulated conductors, although additional personal protection must still be used. The Smart Hold allows increases in measurements to be monitored with an audible tone. The Maximum/Minimum and In-rush modes enable maximum load currents from equipment to be identified such as start-up currents to motors and heaters.

Megger DCM1500S Specifications

DC mV Range: 600 mV
OL reading: 660 mV
Resolution: 0.1 mV
Accuracy: ±(0.7% + 5D)
DC Voltage Range: 600 mV; 1000 V
OL reading: 660 mV; 1100 V
Resolution: 0.1 V; 1 V
Accuracy: ±(0.7% + 2D)
AC Voltage Range: 600 mV; 1000 V
OL reading: 660 mV; 1100 V
Resolution: 0.1 V; 1 V
Accuracy: ±(1% + 5D)
PV DC Voltage (using PVHV1 or PVHV2 lead set) Range: 600 mV; 2000 V
OL reading: 660 mV; 2200 V
Resolution: 0.1 V; 1 V
Accuracy: (2% + 5D)
PV AC Voltage (using PVHV1 or PVHV2 lead set) Range: 600 mV; 1500 V
OL reading: 660 mV; 1600 V
Resolution: 0.1 V; 1 V
Accuracy: (2% + 5D)
AC/DC μA Range: 400 μA; 4000 μA
OL reading: 440 μA; 4400 μA
Resolution: 0.1 μA; 1 μA
Accuracy: ±(1% + 3D
AC/DC Current Range: 60 A; 600 A; 1500 A
OL reading: 66 A; 660 A; 1550 A
Resolution: 0.01 A; 0.1 A; 1 A
Accuracy: ±(2% + 5D)
Frequency Range: 100 Hz; 1000 Hz; 10 kHz
OL reading: 100 Hz; 1000 Hz; 10 kHz
Resolution: 0.01 Hz; 0.1 Hz; 0.001 kHz
Accuracy: ±(0.3% + 3D)
Resistance Range: 600 Ω; 6 kΩ; 60 kΩ; 600 kΩ
OL reading: 660 Ω; 6.6 kΩ; 66 kΩ; 660 kΩ
Resolution: 0.1 Ω; 0.001 kΩ; 0.01 kΩ; 0.1 kΩ
Accuracy: ±(0.9% + 5D); ±(0.9% + 2D)
Continuity Built-in buzzer sounds when measured resistance is less than 20 Ω and the sound is off when measured resistance is more than 200 Ω, between 20 to 200 Ω the buzzer may be either on or off
Diode Range: 1.5 V
OL reading: 1.55 V
Resolution: 0.001 V
Accuracy: ±(0.9% + 2D)
Capacitance Range: 100 μF; 1000 μF
OL reading: 110 μF; 1100 μF
Resolution: 0.1 μF; 1 μF
Accuracy: ±(1.9% + 2D)
VoltSeek Voltage range of high sensitivity: 80 to 1000 V (at the top edge of the jaw)
Voltage range of low sensitivity: 160 to 1000 V (at the top edge of the jaw)
Temperature Range: -40 to 752°F (-40 to 400°C)
OL reading: 824°F (440°C)
Resolution: 0.1°F (0.1°C)
Accuracy: ±1% + 36D (±1% + 20D)
The accuracy does not include the accuracy of the thermocouple probe. Accuracy specification assumes surrounding temperature stable to ±1°C. For surrounding temperature changes of ±2°C rated accuracy applies after 2 hours
Click here for complete specifications on the Megger DCM1500S

What's included with the Megger DCM1500S

  • Solar Clamp Meter
  • Lead Set
  • K-Type Thermocouple Probe
  • 2 x Leads
  • Carrying Case
  • Three-Year Warranty

Click on a category to view a selection of compatible accessories with the Megger DCM1500S Solar Clamp Meter, 2000 V DC, 1500 V AC.

Megger PVHV1 Lead Set with 0.16" plugs for the DCM1500S PVHV1
The test leads are replacements for the DCM1500S clamp meter. They can perform accurate measurements on PV systems.




Megger PVHV2 Lead Set with MC4 PV plugs for the DCM1500S PVHV2
The test leads are replacements for the DCM1500S clamp meter. Use them to help take accurate measurements of PV systems.




Megger 1013-358 Lead Set for the DCM1500S, 0.16" 1013-358
The lead set provides replacement accessories, including probes and crocodile clips. The set measures 0.16" (4 mm).




Megger 1013-364 TP-90 Type-K Thermocouple Probe for the DCM1500S 1013-364
The TP-90 probe measures temperature accurately. It's for use with a solar clamp meter.




Ask a question about Megger DCM1500S Solar Clamp Meter, 2000 V DC, 1500 V AC

Customer Reviews for the Megger DCM1500S

Megger DCM1500S Offers

Remotely monitor measurement values on a smart device with this solar clamp meter which features built-in Bluetooth to view a live trend graph and sample and log the values for later analysis. Additionally, this meter features a high-frequency rejection filter, inrush current measurement, internal data logging, a non-contact volt seek mode, and manual DC Amp zeroing.

Features

  • 2000 V DC
  • TRMS 1500 V AC
  • 1500 A AC/DC
  • Smart hold
  • Auto ranging
  • Minimum/Maximum hold
  • Inrush current
  • Megger Link app compatible
  • CAT IV 600 V / CAT III 1000 V
  • Data logger
  • PV test leads with MC4PV plugs
  • 60000 counts digital display
  • Large white LED backlit display
  • True RMS reading on ACA/ACV
  • AC/DC μA Range
  • Resistance, diode, capacitance and frequency measurement
  • °C/°F temperature function
  • DCA zero
  • Torch light on trigger push
  • Data Logging up to 1000 records
  • Manual save mode
  • Auto power off
  • DC mV Range

Applications

  • Solar/photovoltaic installations
  • Electrical systems and equipment
  • Battery monitoring
  • Automotive
  • Charging and load circuits
  • Electric vehicle servicing
  • Lift maintenance
  • UPS commissioning, servicing and maintenance
  • Electro-plating plants and welding equipment servicing
  • Domestic power generation from solar panels and wind-turbines

The unit is designed to be used on electrical systems and equipment, including solar/photovoltaic installations where, there is a need to measure current, volts, resistance and frequency. It is therefore intended for use while installing, maintaining, fault-finding or monitoring those systems. The tactile barrier below the jaws of the instrument ensures a safe working distance for the operator's hand when measuring current on live uninsulated conductors, although additional personal protection must still be used. The Smart Hold allows increases in measurements to be monitored with an audible tone. The Maximum/Minimum and In-rush modes enable maximum load currents from equipment to be identified such as start-up currents to motors and heaters.

Megger DCM1500S Specifications

DC mV Range: 600 mV
OL reading: 660 mV
Resolution: 0.1 mV
Accuracy: ±(0.7% + 5D)
DC Voltage Range: 600 mV; 1000 V
OL reading: 660 mV; 1100 V
Resolution: 0.1 V; 1 V
Accuracy: ±(0.7% + 2D)
AC Voltage Range: 600 mV; 1000 V
OL reading: 660 mV; 1100 V
Resolution: 0.1 V; 1 V
Accuracy: ±(1% + 5D)
PV DC Voltage (using PVHV1 or PVHV2 lead set) Range: 600 mV; 2000 V
OL reading: 660 mV; 2200 V
Resolution: 0.1 V; 1 V
Accuracy: (2% + 5D)
PV AC Voltage (using PVHV1 or PVHV2 lead set) Range: 600 mV; 1500 V
OL reading: 660 mV; 1600 V
Resolution: 0.1 V; 1 V
Accuracy: (2% + 5D)
AC/DC μA Range: 400 μA; 4000 μA
OL reading: 440 μA; 4400 μA
Resolution: 0.1 μA; 1 μA
Accuracy: ±(1% + 3D
AC/DC Current Range: 60 A; 600 A; 1500 A
OL reading: 66 A; 660 A; 1550 A
Resolution: 0.01 A; 0.1 A; 1 A
Accuracy: ±(2% + 5D)
Frequency Range: 100 Hz; 1000 Hz; 10 kHz
OL reading: 100 Hz; 1000 Hz; 10 kHz
Resolution: 0.01 Hz; 0.1 Hz; 0.001 kHz
Accuracy: ±(0.3% + 3D)
Resistance Range: 600 Ω; 6 kΩ; 60 kΩ; 600 kΩ
OL reading: 660 Ω; 6.6 kΩ; 66 kΩ; 660 kΩ
Resolution: 0.1 Ω; 0.001 kΩ; 0.01 kΩ; 0.1 kΩ
Accuracy: ±(0.9% + 5D); ±(0.9% + 2D)
Continuity Built-in buzzer sounds when measured resistance is less than 20 Ω and the sound is off when measured resistance is more than 200 Ω, between 20 to 200 Ω the buzzer may be either on or off
Diode Range: 1.5 V
OL reading: 1.55 V
Resolution: 0.001 V
Accuracy: ±(0.9% + 2D)
Capacitance Range: 100 μF; 1000 μF
OL reading: 110 μF; 1100 μF
Resolution: 0.1 μF; 1 μF
Accuracy: ±(1.9% + 2D)
VoltSeek Voltage range of high sensitivity: 80 to 1000 V (at the top edge of the jaw)
Voltage range of low sensitivity: 160 to 1000 V (at the top edge of the jaw)
Temperature Range: -40 to 752°F (-40 to 400°C)
OL reading: 824°F (440°C)
Resolution: 0.1°F (0.1°C)
Accuracy: ±1% + 36D (±1% + 20D)
The accuracy does not include the accuracy of the thermocouple probe. Accuracy specification assumes surrounding temperature stable to ±1°C. For surrounding temperature changes of ±2°C rated accuracy applies after 2 hours
Click here for complete specifications on the Megger DCM1500S

What's included with the Megger DCM1500S

  • Solar Clamp Meter
  • Lead Set
  • K-Type Thermocouple Probe
  • 2 x Leads
  • Carrying Case
  • Three-Year Warranty

Click on a category to view a selection of compatible accessories with the Megger DCM1500S Solar Clamp Meter, 2000 V DC, 1500 V AC.

Megger PVHV1 Lead Set with 0.16" plugs for the DCM1500S PVHV1
The test leads are replacements for the DCM1500S clamp meter. They can perform accurate measurements on PV systems.




Megger PVHV2 Lead Set with MC4 PV plugs for the DCM1500S PVHV2
The test leads are replacements for the DCM1500S clamp meter. Use them to help take accurate measurements of PV systems.




Megger 1013-358 Lead Set for the DCM1500S, 0.16" 1013-358
The lead set provides replacement accessories, including probes and crocodile clips. The set measures 0.16" (4 mm).




Megger 1013-364 TP-90 Type-K Thermocouple Probe for the DCM1500S 1013-364
The TP-90 probe measures temperature accurately. It's for use with a solar clamp meter.




Ask a question about Megger DCM1500S Solar Clamp Meter, 2000 V DC, 1500 V AC

Customer Reviews for the Megger DCM1500S

More Megger Products