With its capability to perform both basic, or more complex flue gas analysis, maintenance or safety checks, or confirm furnace efficiency, this combustion analyzer delivers more combustion parameters. The stainless steel probe and cone-stop is perfect for residential, and boiler applications. The analyzer can be used for accurate heating adjustments, so you can get it right the first time - every time. With five different fuels to select from (natural gas, propane, fuel oil 2, biomass 5%, wood 20%), it provides the flexibility you need for your tuning opportunities. With an optional printer kit available, you are able to keep records of all readings taken.
Measures
Features
Applications
Temperature - Type K TC | |
---|---|
Measuring Range | -4 to 212°F (-20 to +100°C) |
Resolution | 0.1°F (0.1°C) |
Reaction Time | < 50 sec |
Temperature - Type J TC | |
Measuring Range | 32° to 752°F (0 to +400°C) |
Accuracy | ±1.8°F; 32 to 212°F (±1°C; 0 to +100°C) ±1.5% of mv; > 212°F (±1.5% of mv; > 100°C) |
Resolution | 0.1°F (0.1°C) |
Reaction Time | < 50 seconds |
Flue Gas O2 | |
Measuring Range | 0 to 21 Vol.% |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Reaction Time t90 | 30 sec |
Flue Gas Draft | |
Measuring Range | -8 to 8 InH2O (-20 to 20 hPa) |
Accuracy | ±0.01 InH2O (-1.20 to +1.20 InH2O) ±0.03 hPa (-3.00 to +3.00 hPa) ±1.5% of mv (remaining range) |
Resolution | 0.01 InH2O (0.01 hPa) |
Efficiency | |
Measuring Range | 0 to 120% |
Resolution | 0.1 % |
General Specifications | |
Temperature | Operating: 23 to 113°F (-5 to +45°C) Storage: -4 to 122°F (-20 to +50°C) |
Display | Type: LCD Function: Backlit 2-line display |
Power Supply | Battery: 1500 mAh, mains unit 5 V/1 A |
Dimensions | 8 x 3 x 2" (201 x 83 x 44 mm) |
Weight | Approx. 25 oz. (700 g) with probe |
Temperature - Type K TC | |
---|---|
Measuring Range | -4 to 212°F (-20 to +100°C) |
Resolution | 0.1°F (0.1°C) |
Reaction Time | < 50 sec |
Temperature - Type J TC | |
Measuring Range | 32° to 752°F (0 to +400°C) |
Accuracy | ±1.8°F; 32 to 212°F (±1°C; 0 to +100°C) ±1.5% of mv; > 212°F (±1.5% of mv; > 100°C) |
Resolution | 0.1°F (0.1°C) |
Reaction Time | < 50 seconds |
Flue Gas O2 | |
Measuring Range | 0 to 21 Vol.% |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Reaction Time t90 | 30 sec |
Flue Gas Draft | |
Measuring Range | -8 to 8 InH2O (-20 to 20 hPa) |
Accuracy | ±0.01 InH2O (-1.20 to +1.20 InH2O) ±0.03 hPa (-3.00 to +3.00 hPa) ±1.5% of mv (remaining range) |
Resolution | 0.01 InH2O (0.01 hPa) |
Efficiency | |
Measuring Range | 0 to 120% |
Resolution | 0.1 % |
General Specifications | |
Temperature | Operating: 23 to 113°F (-5 to +45°C) Storage: -4 to 122°F (-20 to +50°C) |
Display | Type: LCD Function: Backlit 2-line display |
Power Supply | Battery: 1500 mAh, mains unit 5 V/1 A |
Dimensions | 8 x 3 x 2" (201 x 83 x 44 mm) |
Weight | Approx. 25 oz. (700 g) with probe |